ACCUNIQ BC720 vs InBody 970
ACCUNIQ BC720 and InBody 970: compare documented specifications, features and limitations. Check the reports and explanation offered by the provider. More features alone do not establish better accuracy.
ACCUNIQ BC720: when to consider it
ACCUNIQ BC720 uses multi-frequency BIA with eight contact electrodes. Results include estimated whole-body and regional fat and muscle for the arms, legs and trunk. BC720 also reports extracellular water and phase angle.
InBody 970: when to consider it
InBody 970/970S is a professional series for segmental body-composition analysis, including body water and phase angle. The variants differ in frequencies and testing time; location details identify the exact model.
Specifications side by side
The filter keeps rows with undocumented values. More features or a different value alone do not establish better measurement accuracy.
Practical specifications
| Specification | ACCUNIQ BC720 | InBody 970 |
|---|---|---|
| Maximum weightA documented value is missing | 270 kgModel sources | Not documented |
| Recording timeA documented value is missing | Not documented | ≈ 70 sModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 |
| Body weight rangeA documented value is missing | Not documented | 5–300 kgModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 |
| Height rangeA documented value is missing | Not documented | 95–220 cmModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 |
| Measurement positionA documented value is missing | Not documented | StandingModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 |
| Age in the cited catalogueA documented value is missing | Not documented | 3–99 yearsEvidence |
Technical specifications
| Specification | ACCUNIQ BC720 | InBody 970 |
|---|---|---|
| MethodA documented value is missing | Multi-frequency BIAModel sources | Not documented |
| Measurement frequenciesDifferent documented values | 1, 5, 50, 250, 550, 1000 kHzModel sources | 1, 5, 50, 250, 500 kHz; 1, 2, 3 MHzModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 |
| ElectrodesA documented value is missing | 8 contact electrodesModel sources | Not documented |
| Measured regionsA documented value is missing | Both arms, both legs and trunkModel sources | Not documented |
| Device weightA documented value is missing | Not documented | 46 kgModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 |
| Contact electrodesA documented value is missing | Not documented | 8Model sources 1Model sources 2Model sources 3Model sources 4Model sources 5 |
| Method and electrodesA documented value is missing | Not documented | DSM-BIA / SMF-BIA; 8 tactile electrodesModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 |
| Measured segmentsA documented value is missing | Not documented | Right and left arm, trunk, right and left legModel sources 1Model sources 2Model sources 3Model sources 4Model sources 5 |
| Dimensions (width × depth × height)A documented value is missing | Not documented | 614.1 × 963.8 × 1,239.9 mmEvidence |
| Impedance measurementsA documented value is missing | Not documented | 40Evidence |
| Device internal database capacityA documented value is missing | Not documented | 100,000 recordsModel sources |
| DisplayA documented value is missing | Not documented | 10.1″ colour TFT LCD; 1,280 × 800Model sources |
| Display diagonalA documented value is missing | Not documented | 10.1″Model sources |
| Documented interfacesA documented value is missing | Not documented | 4× RS-232C, 2× USB host, USB device, Ethernet, Wi-Fi, BluetoothModel sources |
Fat-free mass is not pure muscle mass. A single result is not a diagnosis. Different devices and similarly named metrics may use definitions that are not interchangeable.