InBody 170 vs Tanita BC-601
InBody 170 and Tanita BC-601: compare documented specifications, features and limitations. Check the reports and explanation offered by the provider. More features alone do not establish better accuracy.
InBody 170: when to consider it
The older InBody170 provides a basic overview for weight loss and muscle-building goals. It can also help you follow existing measurements: a consultation can examine changes in fat, muscle and their distribution.
Tanita BC-601: when to consider it
BC-601 is a segmental scale for tracking fat and muscle mass in five body regions. Its display sits on a pull-up handle and results can be stored on an SD card. Weight capacity is 150 kg; consistent preparation and interpretation matter when comparing changes.
Specifications side by side
Highlighted rows differ. Unknown values stay unknown.
| Specifications | InBody 170 | Tanita BC-601 |
|---|---|---|
| Recording time | 30 s | Not verified |
| Body weight range | 10–250 kg | Not verified |
| Height range | 95–220 cm | Not verified |
| Device weight | 14.3 kg | Not verified |
| Measurement frequencies | 20, 100 kHz | Not verified |
| Contact electrodes | 8 | Not verified |
| Measurement position | Standing | Not verified |
| Operating temperature | 10–40 °C | Not verified |
| Method | Not verified | Bioelectrical impedance (BIA) |
| Maximum weight | Not verified | 150 kg |
| Measured regions | Not verified | Both arms, both legs and trunk |
| Documented outputs | Not verified | Whole-body and regional fat and muscle mass |
| Result display | Not verified | Handle display; SD card |
| Dimensions (width × depth × height) | 396 × 608 × 955 mmEvidence | Not verified |
| Age in the cited catalogue | 3–99 yearsEvidence | Not verified |
| Impedance measurements | 10Evidence | Not verified |
| Display | EBTN LCD and buttonsEvidence | Not verified |
| Documented interfaces | RS-232C and USB connection to a computer; compatibility depends on the original software.Model sources | Not verified |
| Result sheet | Thermal printout; further result handling depends on the original softwareModel sources | Not verified |
| Height entry | Height is entered; the analyser itself does not measure itModel sources | Not verified |
Fat-free mass is not pure muscle mass. A single result is not a diagnosis. Different devices and similarly named metrics may use definitions that are not interchangeable.
Sources and verification
- InBody170 User’s Manual — BM-ENG1-C0-B-120903
- Biospace — FDA K130777, srovnávací tabulka
- FIT V RÁJI — měření na InBody 170
- Sport Centrum Evropská — InBody 170
- InBody CZ — podpora starších přístrojů
- FDA — InBody170, K110689 (2011)
- TANITA Asia Pacific — BC-601
- Investigators — BC-601 body composition methods (2024)