Comparison

InBody 380 vs InBody 970S

InBody 380 and InBody 970S: compare documented specifications, features and limitations. Check the reports and explanation offered by the provider. More features alone do not establish better accuracy.

InBody 380: when to consider it

For following fat and muscle changes at a gym, nutrition practice or mobile testing event. Adds a body-water ratio and whole-body phase angle to the usual overview for discussion during a consultation.

InBody 970S: when to consider it

For a comprehensive consultation when you want to follow water distribution and phase angles alongside fat and muscle. This newer 970 generation offers detailed outputs for clinical, nutrition, sports and research settings.

Specifications side by side

Highlighted rows differ. Unknown values stay unknown.

SpecificationsInBody 380InBody 970S
Recording time≈ 30 s≈ 30 s
Body weight range5–300 kg2–300 kg
Height range95–220 cm95–220 cm
Device weight16 kg41.1 kg
Measurement frequencies5, 50, 500 kHz5, 50, 250, 500 kHz; 1, 3 MHz
Contact electrodes88
Measurement positionStandingStanding
Operating temperature10–40 °CNot verified
Method and electrodesNot verifiedDSM-BIA / SMF-BIA; 8 tactile electrodes
Measured segmentsNot verifiedRight and left arm, trunk, right and left leg
Dimensions (width × depth × height)415.5 × 871.5 × 1,069.9 mmEvidence614.1 × 963.8 × 1,239.3 mmEvidence
Age in the cited catalogueFrom 3 yearsEvidenceFrom 3 yearsEvidence
Impedance measurements15Evidence30Evidence
Device internal database capacity100,000 recordsEvidence100,000 recordsModel sources
Display7″ touchscreen TFT LCD, 480 × 800Evidence10.1″ colour TFT LCD; 1,280 × 800Model sources
Display diagonal7″Model sources10.1″Model sources
Documented interfaces2× RS-232C, 2× USB host, Ethernet, Bluetooth and Wi-FiModel sourcesWi-Fi, BluetoothModel sources
ConstructionFolding column and three-way hand electrodesModel sourcesNot verified
Result sheetsBody composition, child and thermal reportsModel sourcesNot verified
Client identificationID entry and QR recognition option; depends on equipmentModel sourcesNot verified
Operating modesProfessional and self-service modesModel sourcesNot verified
Segmental phase angleNot verified15 values: 5, 50 and 250 kHz × 5 segmentsModel sources
Identification at testingNot verifiedFingerprint / InBodyBAND recognitionModel sources

Fat-free mass is not pure muscle mass. A single result is not a diagnosis. Different devices and similarly named metrics may use definitions that are not interchangeable.

Sources and verification