InBody 270 vs Tanita RD-545HR
InBody 270 and Tanita RD-545HR: compare documented specifications, features and limitations. Check the reports and explanation offered by the provider. More features alone do not establish better accuracy.
InBody 270: when to consider it
The original InBody270 gives a quick overview of fat, muscle and their distribution. It suits regular diet and training consultations, including testing at different locations. Its output coverage differs from the newer 270S.
Tanita RD-545HR: when to consider it
RD-545HR uses dual-frequency segmental BIA with a handle and app connection. It provides fat, muscle and regional results as well as heart rate. HR distinguishes it from the original RD-545; a scale’s bone-mass estimate is distinct from bone densitometry.
Specifications side by side
Highlighted rows differ. Unknown values stay unknown.
| Specifications | InBody 270 | Tanita RD-545HR |
|---|---|---|
| Recording time | ≈ 15 s | Not verified |
| Body weight range | 10–250 kg | Not verified |
| Height range | 95–220 cm | Not verified |
| Device weight | 14 kg | Not verified |
| Measurement frequencies | 20, 100 kHz | Not verified |
| Contact electrodes | 8 | Not verified |
| Measurement position | Standing | Not verified |
| Operating temperature | 10–40 °C | Not verified |
| Method | Not verified | Dual-frequency BIA |
| Maximum weight | Not verified | 200 kg |
| Measured regions | Not verified | Both arms, both legs and trunk |
| Documented outputs | Not verified | Fat, muscle mass, water, regional results and heart rate |
| Dimensions (width × depth × height) | 356 × 796 × 995 mmEvidence | Not verified |
| Age in the cited catalogue | 3–99 yearsEvidence | Not verified |
| Impedance measurements | 10Evidence | Not verified |
| Device internal database capacity | 100,000 recordsModel sources | Not verified |
| Display | 7″ colour touchscreen LCD, keypadModel sources | Not verified |
| Display diagonal | 7″Model sources | Not verified |
| Documented interfaces | RS-232C, USB, LAN, Bluetooth, Wi-FiModel sources | Not verified |
| Electrodes | 8 contact points on hands and feetModel sources | Not verified |
| Report types | Adult, child and optional thermal reportsModel sources | Not verified |
Fat-free mass is not pure muscle mass. A single result is not a diagnosis. Different devices and similarly named metrics may use definitions that are not interchangeable.
Sources and verification
- Nutriamb, Jindřichův Hradec — měření InBody 270
- InBody 270 — originální katalog BC-ENG-83-D-220121
- InBody 270 — český uživatelský manuál
- InBody Japan — změna specifikace 270 → 270S (12. 11. 2024)
- InBody USA — The InBody Test
- Ne hladu — měření InBody230 a 270 / InBody230 and 270 testing
- InBody Japan — BIA and InBody history
- InBody — historie modelů 230 a 270 / history of models 230 and 270
- TANITA Europe — RD-545HR