InBody BWA 2.0S vs Tanita BC-1000
InBody BWA 2.0S and Tanita BC-1000: compare documented specifications, features and limitations. Check the reports and explanation offered by the provider. More features alone do not establish better accuracy.
InBody BWA 2.0S: when to consider it
The newer BWA 2.0S combines detailed water results with composition and offers a shorter test than the original BWA. Testing can also take place while lying or seated. It is mainly intended for care where a professional follows water distribution and muscle quantity over time.
Tanita BC-1000: when to consider it
BC-1000 is a body-composition scale that transmits results wirelessly to a compatible receiver. Its manual lists fat, muscle and body water; capacity is 200 kg. BC-1000 Plus is a different version; accessories may vary in a package labelled “PROFI”.
Specifications side by side
Highlighted rows differ. Unknown values stay unknown.
| Specifications | InBody BWA 2.0S | Tanita BC-1000 |
|---|---|---|
| Recording time | ≈ 30 s (Medical); ≈ 60 s (Research) | Not verified |
| Body weight range | 2–250 kg | Not verified |
| Height range | 95–220 cm | Not verified |
| Device weight | 2.8 kg | Not verified |
| Measurement frequencies | 5, 50, 250, 500 kHz; 1, 3 MHz | Not verified |
| Contact electrodes | 16 | Not verified |
| Measurement position | Supine, seated or standing | Not verified |
| Operating temperature | 10–40 °C | Not verified |
| Method | Not verified | Bioelectrical impedance (BIA) |
| Maximum weight | Not verified | 200 kg |
| Documented outputs | Not verified | Body fat, muscle mass and body water |
| Result display | Not verified | Compatible wireless receiver / external display |
| Dimensions (width × depth × height) | 322 × 282 × 81.5 mmEvidence | Not verified |
| Age in the cited catalogue | From 3 yearsEvidence | Not verified |
| Impedance measurements | 30Evidence | Not verified |
| Device internal database capacity | 100,000 recordsEvidence | Not verified |
| Display | Colour touchscreen TFT LCD, 1280 × 800 pixelsEvidence | Not verified |
| Documented interfaces | RS-232C, USB Host, USB Slave, Ethernet, Bluetooth and Wi-FiEvidence | Not verified |
| Display diagonal | 10.1″Model sources | Not verified |
| Contacts and modes | Clamp electrodes; Medical (proximal) and Research (distal) placementModel sources | Not verified |
| Weight for the test | Entered separately; no built-in scaleModel sources | Not verified |
| Z0 and Z∞ | Modelled limiting impedances, rather than additional measured frequenciesModel sources | Not verified |
Fat-free mass is not pure muscle mass. A single result is not a diagnosis. Different devices and similarly named metrics may use definitions that are not interchangeable.
Sources and verification
- InBody — BWA2.0S katalog / catalogue
- InBody — BWA2.0S User’s Manual (2025)
- InBody CZ — BWA2S
- InBody USA — BWA 2.0S
- InBody UK — BWA 2.0S
- InBody — BWA 2.0 catalogue (2021)
- InBody — Annual Report 2025, company history
- FDA / NLM — BWA2.0S, GUDID (2024)
- TANITA — BC-1000 instruction manual
- Investigators — BC-1000 body composition methods (2024)

